In the EEG frequency spectrum, one often sees a strong deflection at exactly 50 Hz. What
is this due to?

Lösung anzeigen
TESTE DEIN WISSEN

Gamma oscillations in the brain

Lösung ausblenden
TESTE DEIN WISSEN

The C1 visual component is an [exogenous/endogenous] EKP component that occurs
[before/after] the P300 component

Lösung anzeigen
TESTE DEIN WISSEN

exogenous, before the P300

Lösung ausblenden
TESTE DEIN WISSEN

Which statement regarding the amplitude of the EEG signal recorded by electrodes over
the head is true?

Lösung anzeigen
TESTE DEIN WISSEN

It is much smaller than either the ECG or EMG signals described above.


Lösung ausblenden
TESTE DEIN WISSEN

Impedance is specified in units of....

Lösung anzeigen
TESTE DEIN WISSEN

Microvolt

Lösung ausblenden
TESTE DEIN WISSEN

A subject presses a key with the left hand or foot. At which EEG electrode would you
expect to have the strongest lateralized readiness potential?

Lösung anzeigen
TESTE DEIN WISSEN

Hand response: Oz, foot response: Fz.

Lösung ausblenden
TESTE DEIN WISSEN

.Measurement methodology: the presentation of a visual stimulus triggers a P1 component
in the EEG. How would you classify this biosignal?

Lösung anzeigen
TESTE DEIN WISSEN

evoked and tonic

Lösung ausblenden
TESTE DEIN WISSEN

Measurement methodology: An EEG recording was low-pass analog filtered at 50 Hz
before analog-to-digital conversion (sampling rate: 200 Hz). Can apparent frequencies
(aliasing) still occur in the signal? And what should be done?

Lösung anzeigen
TESTE DEIN WISSEN

Yes. Therefore, the digitized signal must still be low-pass filtered at 100 Hz.

Lösung ausblenden
TESTE DEIN WISSEN

Which one is not EEG artifacts

Lösung anzeigen
TESTE DEIN WISSEN

Ocular activity

Lösung ausblenden
TESTE DEIN WISSEN

Which ERP components fit the description in the following order: Automatic detection of
stimulus deviance or novelty, Task-dependent categorization, face processing; Initial sensory
repones

Lösung anzeigen
TESTE DEIN WISSEN

P2; P300; P1; N170

Lösung ausblenden
TESTE DEIN WISSEN

Which waves fall into the 12-38 Hz that dominate when we are awake, alert and engaged;
which waves dominates when we are in a period of deep sleep; which waves dominates when
we have completed a task and sit down to rest; which waves are strong in the drowsy state
before sleep in infants, adolescents and adults.

Lösung anzeigen
TESTE DEIN WISSEN

Delta, alpha, theta, Beta

Lösung ausblenden
TESTE DEIN WISSEN

Measurement methodology: Which sequence in the acquisition of biosignals is logical?

Lösung anzeigen
TESTE DEIN WISSEN

1. transducer, 2. sensor, 3. A/D converter, 4. digital filtering

Lösung ausblenden
TESTE DEIN WISSEN

Which description is TRUE between fixation and saccades?

Lösung anzeigen
TESTE DEIN WISSEN

Fixation has a typical mean duration of about 20 to 40 ms.

Lösung ausblenden
  • 216344 Karteikarten
  • 3437 Studierende
  • 106 Lernmaterialien

Beispielhafte Karteikarten für deinen Psychophysiological Methods in Research and Practice Kurs an der Freie Universität Berlin - von Kommilitonen auf StudySmarter erstellt!

Q:

In the EEG frequency spectrum, one often sees a strong deflection at exactly 50 Hz. What
is this due to?

A:

Gamma oscillations in the brain

Q:

The C1 visual component is an [exogenous/endogenous] EKP component that occurs
[before/after] the P300 component

A:

exogenous, before the P300

Q:

Which statement regarding the amplitude of the EEG signal recorded by electrodes over
the head is true?

A:

It is much smaller than either the ECG or EMG signals described above.


Q:

Impedance is specified in units of....

A:

Microvolt

Q:

A subject presses a key with the left hand or foot. At which EEG electrode would you
expect to have the strongest lateralized readiness potential?

A:

Hand response: Oz, foot response: Fz.

Mehr Karteikarten anzeigen
Q:

.Measurement methodology: the presentation of a visual stimulus triggers a P1 component
in the EEG. How would you classify this biosignal?

A:

evoked and tonic

Q:

Measurement methodology: An EEG recording was low-pass analog filtered at 50 Hz
before analog-to-digital conversion (sampling rate: 200 Hz). Can apparent frequencies
(aliasing) still occur in the signal? And what should be done?

A:

Yes. Therefore, the digitized signal must still be low-pass filtered at 100 Hz.

Q:

Which one is not EEG artifacts

A:

Ocular activity

Q:

Which ERP components fit the description in the following order: Automatic detection of
stimulus deviance or novelty, Task-dependent categorization, face processing; Initial sensory
repones

A:

P2; P300; P1; N170

Q:

Which waves fall into the 12-38 Hz that dominate when we are awake, alert and engaged;
which waves dominates when we are in a period of deep sleep; which waves dominates when
we have completed a task and sit down to rest; which waves are strong in the drowsy state
before sleep in infants, adolescents and adults.

A:

Delta, alpha, theta, Beta

Q:

Measurement methodology: Which sequence in the acquisition of biosignals is logical?

A:

1. transducer, 2. sensor, 3. A/D converter, 4. digital filtering

Q:

Which description is TRUE between fixation and saccades?

A:

Fixation has a typical mean duration of about 20 to 40 ms.

Psychophysiological Methods in Research and Practice

Erstelle und finde Lernmaterialien auf StudySmarter.

Greife kostenlos auf tausende geteilte Karteikarten, Zusammenfassungen, Altklausuren und mehr zu.

Jetzt loslegen

Das sind die beliebtesten StudySmarter Kurse für deinen Studiengang Psychophysiological Methods in Research and Practice an der Freie Universität Berlin

Für deinen Studiengang Psychophysiological Methods in Research and Practice an der Freie Universität Berlin gibt es bereits viele Kurse, die von deinen Kommilitonen auf StudySmarter erstellt wurden. Karteikarten, Zusammenfassungen, Altklausuren, Übungsaufgaben und mehr warten auf dich!

Mehr Karteikarten anzeigen

Das sind die beliebtesten Psychophysiological Methods in Research and Practice Kurse im gesamten StudySmarter Universum

Archeology: Theory, methods and practice

University of Wroclaw

Zum Kurs
Research and methods

University of Amsterdam

Zum Kurs
Methods and Strats in Brain Research

Kingston University

Zum Kurs
Methods and Strategies in Brain Research

Kingston University

Zum Kurs
Research in Psychology

London Metropolitan University

Zum Kurs

Die all-in-one Lernapp für Studierende

Greife auf Millionen geteilter Lernmaterialien der StudySmarter Community zu
Kostenlos anmelden Psychophysiological Methods in Research and Practice
Erstelle Karteikarten und Zusammenfassungen mit den StudySmarter Tools
Kostenlos loslegen Psychophysiological Methods in Research and Practice